全部文献

广谱长脉冲红外设备改善面部皮肤老化的临床评估

2026年10月20日45 min read

Biomedicines

广谱长脉冲红外设备改善面部皮肤老化的临床评估
本文目录

结论与实践要点

一分钟要点

  • 单臂前瞻性研究纳入30例面部皮肤松弛与光损伤患者(25女5男,均龄47.1,Fitzpatrick I–IV),接受单次广谱长脉冲红外(Zaffiro)治疗,波长750–1800 nm、能量密度35–45 J/cm²。
  • 皮肤弹性Cutometry显著改善:基线58.92,第5天68.37(+16.03%),第21天72.11(+22.38%),第150天73.27(+24.35%),呈渐进式提升。
  • 皮肤水合仅轻度上升(第21天约+2.69%,第150天回落至约+2.04%),提示可能为短暂表皮屏障调节而非持久真皮重塑。
  • 组织学(3例耳后活检)示第21天成纤维细胞(Vimentin)较基线增约40%(未达统计学显著);胶原自发荧光在第5天与第150天显著增强。
  • 炎症浸润第5天达峰值(评分2.0)并于第21天回落(1.66),多为轻度、自限,各炎症/血管/成纤维标志物变化均未达统计学显著。
  • 耐受性良好:14/30例(46.67%)出现短暂红斑,持续1–4小时、平均1.85小时,无肿胀或其他明显反应;未见严重不良事件。
  • 5个月患者与7名专家满意度评估总体较高,但专家对肤质与肤色改善的评价较患者更保守。

临床落地解读

①临床定位与机制

广谱长脉冲红外(750–1800 nm)经控温真皮加热,诱导胶原即刻收缩并激活成纤维细胞,促进新生胶原与血管生成,属非剥脱性面部年轻化手段,适用于面部松弛与光损伤。本研究结合生物力学(Cutometry)、组织学与胶原自发荧光,提供该设备的时间分辨再生证据。

②操作/参数要点

  • 单次全面部治疗(含耳后),能量密度35–45 J/cm²;设备含水剥脱预处理与蓝宝石冷却系统以保护表皮。
  • 评估方案:Cutometry测弹性/水合(22–23℃、湿度55–60%标准化);耳后活检(3例)于第0/5/21/150天取材,行H&E、Masson三色与CD68/CD4/CD8/CD20/CD31/Vimentin免疫组化及胶原自发荧光。
  • 患者与专家于5个月进行满意度/改善度五分制评估。

③风险与局限

  • 排除标准含6个月内口服/外用维A酸、光敏性疾病、活动性疱疹、免疫低下、妊娠、未控糖尿病、Fitzpatrick VI型、治疗区文身、抗炎药物等。
  • 主要短暂反应为红斑(平均1.85小时),未见肿胀或严重不良事件;术后按ISO 14155:2020与赫尔辛基宣言执行。

④证据边界

本研究为单臂、无对照、样本较小的探索性研究;组织学仅3例耳后活检(与面部皮肤存在解剖差异),且多数组织学/免疫组化变化未达统计学显著,应视为趋势性而非确证性证据。随访至150天,长期持久性未明。患者自评红斑所用ICDRG量表非美容验证工具,可能引入主观偏倚。结论需更大样本、含面部取样与对照臂的研究进一步确认。

文献原文与证据

Abstract 原文摘要

Objectives: To evaluate the cellular and clinical responses to facial treatment using a wide-spectrum, long-pulse infrared medical device. Methods: Thirty patients with facial skin laxity and photodamage underwent a single treatment session with the infrared device. Skin biopsies were collected before treatment and on days 5 and 21 for histological and immunohistochemical assessments of inflammatory and regenerative changes. Long-term outcomes were analyzed by biomechanical measurements (cutometry) and collagen autofluorescence quantification from histological samples. Results: Histological analysis demonstrated a 40% increase in fibroblast count, angiogenesis, and mild inflammatory activity, though these changes did not reach statistical significance. Cutometric evaluation revealed a significant improvement in skin elasticity at day 21 (+15.97%) and day 150 (+24.49%) post-treatment, accompanied by a modest increase in hydration. Collagen autofluorescence showed a statistically significant enhancement, consistent with ECM remodeling and fibroblast activation. Conclusions: A single session of treatment with a wide-spectrum, long-pulse infrared device produced measurable improvements in dermal elasticity and collagen organization with minimal inflammatory response. These findings support the efficacy and safety of infrared energy-based therapy as a noninvasive modality for facial skin rejuvenation.

Keywords: infrared energy device、facial skin aging、facial skin tightening、thermolifting、esthetic treatment、collagen stimulation

1. Introduction

Facial skin is continuously exposed to both intrinsic and extrinsic aging processes, resulting in structural and functional changes that contribute to visible signs of aging such as laxity, fine lines, and wrinkles. Intrinsic aging, driven largely by genetic and hormonal factors, leads to progressive dermal thinning and reduced fibroblast activity, whereas extrinsic factors, including chronic ultraviolet (UV) radiation, pollution, and lifestyle influences, exacerbate oxidative stress and accelerate collagen degradation. Collectively, these mechanisms diminish dermal elasticity and hydration, resulting in clinically evident photodamage and loss of skin resilience [ 1 , 2 ]. Beyond esthetic concerns, these changes also have functional implications, including impaired barrier function, reduced biomechanical strength, and altered cutaneous physiology.

A growing body of research has focused on noninvasive energy-based technologies as alternatives to surgical interventions for skin rejuvenation. Among these, infrared (IR) devices have gained particular interest due to their ability to penetrate deeply into the dermis, where they induce controlled thermal effects [ 3 ]. This process stimulates neocollagenesis, angiogenesis, and remodeling of extracellular matrix components, ultimately improving tissue elasticity and clinical appearance [ 3 , 4 , 5 , 6 ]. Unlike ablative modalities such as CO 2 or Er:YAG lasers, which involve epidermal disruption and longer recovery times, infrared-based devices can achieve favorable regenerative outcomes with minimal downtime and a favorable safety profile [ 5 , 7 , 8 ].

In addition to energy-based modalities, numerous topical and minimally invasive approaches are employed to counteract facial aging. Topical agents such as retinoids, antioxidants, peptides, and growth-factor-enriched formulations remain foundational due to their ability to enhance epidermal turnover, reduce oxidative stress, and support dermal repair [ 2 , 9 , 10 ]. Alongside these methods, a wide range of injectable techniques has been developed to address dermal atrophy, extracellular matrix disorganization, and soft-tissue volume loss. Injectable treatments, including hyaluronic acid derivatives, collagen-stimulating agents, amino acid–enriched formulations, choline-based solutions, and other biologically active compounds, have demonstrated efficacy in improving hydration, elasticity, and overall skin quality [ 11 , 12 ]. Recent studies show that mesotherapy with low–molecular-weight hyaluronic acid fragments or combinations of hyaluronic acid and choline enhances collagen production, angiogenesis, and epidermal thickness, contributing to visible rejuvenation and high patient satisfaction [ 13 , 14 , 15 ]. Additionally, agents such as botulinum toxin, deoxycholic acid, and synthetic fillers further expand therapeutic possibilities for dynamic wrinkles, localized adiposity, and structural deficiencies [ 11 ]. Taken together, these modalities highlight the multimodal nature of contemporary facial rejuvenation, integrating topical treatments, injectables, and energy-based devices tailored to individual clinical and anatomical needs.

The infrared thermolifting device evaluated in the present study represents a class of non-invasive technologies designed to improve skin firmness, elasticity, and overall facial appearance through controlled dermal heating. By delivering long-pulse infrared energy to deeper skin layers, the device induces a progressive increase in dermal temperature that leads to immediate collagen fiber contraction and stimulates fibroblast activity. These thermal effects activate neocollagenesis and promote remodeling of the extracellular matrix, resulting in enhanced tissue tension, improved skin quality, and visible reductions in early signs of facial laxity [ 16 ]. Clinical outcomes reported for infrared thermolifting include improvements in cutometric skin elasticity, smoother surface texture, and high patient satisfaction. However, despite these documented functional and esthetic benefits, comprehensive biological evidence explaining these effects remains limited. Existing studies provide only partial or preliminary insight into the histological and immunohistochemical changes that accompany infrared-based dermal remodeling. Because the present work specifically investigates tissue responses induced by this infrared device, a deeper understanding of the underlying cellular mechanisms is essential for optimizing treatment parameters and advancing evidence-based clinical application [ 4 , 16 ].

In this study, we sought to evaluate both the short-term histological and immunohistochemical responses, as well as the long-term clinical outcomes, of treatment with a wide-spectrum, long-pulse infrared medical device in patients with facial skin laxity and photodamage. By combining quantitative tissue analyses with biomechanical and optical assessments, we aimed to provide an integrated view of the regenerative processes initiated by infrared therapy.

2. Material and Methods

2.1. Device Used in the Study

The Zaffiro system (Zaffiro Z200NG, Berger & Kraft Medical Sp. z o.o., Warsaw, Poland) is a CE-certified medical device designed for non-invasive skin tightening and rejuvenation using a combination of water-peeling technology and long-pulse broad-spectrum infrared (IR) irradiation. The device delivers controlled IR energy through a sapphire-glass applicator, enabling uniform thermal penetration into the dermis. A preparatory water-peeling module provides precise epidermal exfoliation and improves thermal conductivity, promoting consistent heating of the target structures. Its integrated sapphire cooling system allows safe energy delivery while protecting the epidermis, minimizing discomfort and reducing recovery time [ 16 ].

2.2. Participants and Exclusion Criteria

Thirty patients (25 women and 5 men), aged 25–68 years (mean age 47.1 years) with facial skin laxity and photodamage, and Fitzpatrick skin phototypes I–IV, were enrolled in the study. Patients underwent the treatment protocol described below.

Exclusion criteria included:Use of oral and/or topical retinoids within the last 6 months.Excessive tanning.Active skin or connective tissue diseases associated with photosensitivity (e.g., systemic lupus erythematosus, porphyria cutanea tarda).Active herpes simplex infection.Use of drugs or photoreactive cosmetics within the last 6 months, including: ▪Tetracycline antibiotics.▪Immunosuppressive agents (e.g., corticosteroids and derivatives).▪Anticoagulants (e.g., dipyridamole, coumarin derivatives).▪Cosmetics containing thyme extract or herbal products such as St. John’s wort. Immunodeficiency disorders (including active HIV infection).Fitzpatrick skin phototype VI.Pregnancy (as a precaution).Uncontrolled diabetes mellitus.Previous cosmetic or esthetic procedures in the treatment area (eligibility determined by the physician depending on the procedure performed).Acquired vitiligo or other disorders of melanin production (e.g., hypermelanosis).Tattoos in the areas designated for treatment.Use of anti-inflammatory medications.

Each patient signed an informed consent. The leading standard adopted in this study was ISO 14155:2020 (clinical investigation of medical devices for human subjects—good clinical practice). The study was conducted in accordance with the Declaration of Helsinki, and approved by the Ethics Committee of Medical Chamber in Gdańsk, Poland (protocol code: 2/MATEX/2022; 6 December 2022).

2.3. Treatment Protocol

Day 0: All patients were treated with a wide-spectrum infrared device applied to the entire face, including the area behind the ears (lower retroauricular regions on both sides). The treatment utilized a wavelength range of 750–1800 nm with a fluence of 35–45 J/cm 2 .

2.4. Assessment Protocol

Day 0: Before the treatment, all patients underwent cutometric tests regarding skin elasticity and hydration. The measurements were made on cheeks (in the area of the middle part of the right or left cheek (randomly selected) at intervals of about 1 cm). In addition, a subgroup of 3 patients was randomly selected for histological evaluation. In these patients, skin and subcutaneous tissue samples (taken by surgical excision) were collected by a team of surgical and dermatological specialists experienced in collecting material for histopathological evaluation of treatment safety and efficacy in esthetic procedures using medical devices. The material at day 0 was collected in the area behind the ear in the lower retroauricular region (right side, behind the Lobulus auriculae.

Day 5: All patients underwent cutometric tests regarding skin elasticity and hydration. The measurements were made on both cheeks, three measurements for each cheek. In addition, skin and subcutaneous tissue samples were collected from the subgroup of 3 patients who had been selected at Day 0 for histological evaluation, using surgical excision. The material at day 5 was collected in the area behind the ear in the lower retroauricular region (left side, behind the Lobulus auriculae ). Samples were collected from the contralateral side of the face to avoid interference with tissue healing from the Day 0 biopsy.

Day 21: All patients underwent cutometric tests regarding skin elasticity and hydration. The measurements were made on both cheeks, three measurements for each cheek. In addition, skin and subcutaneous tissue samples were collected from the subgroup of 3 patients selected at Day 0 for histological evaluation, using surgical excision. Biopsies were obtained from the lower retroauricular region (right side, behind the earlobe) at least 2 cm away from the Day 0 sampling site to avoid interference from ongoing tissue repair processes.

Day 150: All patients underwent cutometric tests regarding skin elasticity and hydration. The measurements were made on both cheeks, three measurements for each cheek. In a subgroup of 3 patients selected at Day 0 for histological evaluation, skin samples were collected using shallow surgical excision. Biopsies were obtained from the lower retroauricular region (left side, behind the earlobe) at least 2 cm away from the Day 5 biopsy site to avoid interference from tissue repair processes. Sampling was limited to the skin layer, as subcutaneous tissue is not assessed in collagen autofluorescence analysis.

2.5. Assessment Methods

  • A.Clinical assessment

Cutometric evaluation

All patients underwent cutometric measurements regarding skin elasticity and hydration. The cutometric evaluation was carried out using the Courage + Khazaka Multi Skin Test Center MC1000 device in standardized conditions of temperature (22–23 °C) and air humidity (55–60%). The procedure of patient preparation for the examination was also standardized (make-up was removed at least one hour before measurement without using alcohol-based products). Measurements were performed by properly trained personnel on the skin of the buccal region. Skin elasticity and hydration were assessed on a 1–100 scale, where 1 represents the worst and 100 the best outcome. Three point-by-point measurements were obtained for each patient, and the average values were recorded in the observation chart for subsequent statistical analysis.

Healing time observation

The assessment of healing time was based on patient self-observation. Two parameters were evaluated: the duration of post-procedural redness and swelling. To minimize subjectivity and standardize reporting, patients were provided with visual reference guidelines adapted from the International Contact Dermatitis Research Group (ICDRG) scale ( Figure 1 ). Although originally developed for evaluating reactions in patch testing for contact dermatitis, the ICDRG scale was selected as a structured, clinical-grade visual tool suitable for guiding consistent self-assessment of transient, mild skin responses. In this study, the scale was used exclusively to support standardized description of short-term erythema rather than for diagnostic purposes. This adaptation strategy allowed participants to classify visible changes more reliably, while acknowledging that the ICDRG scale has not been formally validated for esthetic self-assessment.

Graphical scale of the ICDGR test reading:

Figure 1

Figure 1 Visualization of the International Contact Dermatitis Research Group (ICDRG) scale provided to participants. To enhance scientific clarity, dermatological terminology has been standardized in accordance with ICDRG guidelines. Negative reaction: No visible or palpable change. (?) Doubtful reaction: Subtle erythema, non-palpable erythematous macule; such a response is generally not considered evidence of sensitization. (+) Weak reaction: Palpable erythema suggesting mild edema or infiltration, with or without small papules; no vesicles. (++) Strong reaction: Pronounced edema and infiltration with papules and distinct vesicles. (+++) Extreme reaction: Coalescing vesicles or bullae, occasionally accompanied by superficial erosions. (IR) Irritant reaction: Non-allergic response characterized by shiny or dry skin, erythema, or fine papules.Patient’s satisfaction evaluation

The patients’ satisfaction was assessed on the basis of a survey conducted five months after the procedure. Participants were asked to evaluate the results in terms of skin tightening, reduction in fine wrinkles, changes in skin texture and changes in skin color. Each of the above features was assessed by patients on a five-point scale:(1):No improvement;(2):Poor improvement;(3):Moderate improvement;(4):Good improvement;(5):Very good improvement.

Expert’s evaluation

The expert assessment was carried out by an independent team of seven researchers, each with at least five years of experience in dermatology and/or esthetic medicine. The experts were shown photographs of patients taken immediately before and five months after the procedure. They were blinded to the type of treatment administered. Assessment was performed via an anonymous survey, in which experts evaluated changes in skin tension, fine wrinkles, skin texture, and skin color. Each parameter was rated on a five-point scale:(1):No improvement;(2):Poor improvement;(3):Moderate improvement;(4):Good improvement;(5):Very good improvement.

  • B.Histological assessment

For histological evaluation, three patients were randomly selected for biopsy. The limited number of biopsies reflected a deliberate methodological choice aimed at minimizing invasiveness and patient burden in this pilot study. Full-thickness skin and subcutaneous tissue samples were collected from the retroauricular region at days 0, 5, and 21 to assess collagen content, fibroblast density, neoangiogenesis, and the intensity of procedure-induced inflammation. At day 150, a skin-only biopsy was obtained to evaluate long-term collagen remodeling. The retroauricular area was chosen to avoid visible scarring and to maintain ethical acceptability of repeated sampling. All procedures were conducted under sterile conditions with local anesthesia (lidocaine). To reduce the potential influence of prior biopsies on subsequent tissue responses, samples were taken from anatomically adjacent but non-overlapping sites within the treated region.

Basic staining

Skin samples were fixed for 24 h in neutral 10% buffered formalin (pH 7.2) and processed using an automated histoprocessor (Excelsior™ AS; Thermo Fisher Scientific, Waltham, MA, USA), following standard pathology protocols. The tissue blocks were sectioned at 5 μm for histological analysis and 3–4 μm for immunohistochemistry. Hematoxylin and eosin (H&E) staining was used to evaluate the cellular content and overall tissue architecture. Masson’s trichrome staining (Special Stain Kit Masson’s Trichrome, DiaPath, Martinengo, Italy) was performed to assess collagen structure.

Immunohistochemistry

The immunohistochemical (IHC) staining was performed in the automated slide-processing system BenchMark ® ULTRA (Roche Diagnostics/Ventana Medical Systems, Tucson, AZ, USA) with the ultraView Universal DAB Detection Kit (Roche Diagnostics/Ventana). The following primary antibodies were applied: mouse monoclonal anti-CD68 (KP-1), rabbit monoclonal anti-CD8 (SP57), mouse monoclonal anti-CD20 (L26), mouse monoclonal anti-CD31 (JC70) and mouse monoclonal anti-Vimentin (V9).

Briefly, after deparaffinization and rehydration, heat-induced epitope retrieval was carried out in the Cell Conditioning 1 solution (CC1; Ventana, Camperdown, NSW, Australia) at 72 °C for 68 min. Endogenous peroxidase activity and nonspecific binding sites were blocked by incubating tissue sections with 3% H 2 O 2 for 10 min at room temperature (RT) and 3% bovine serum albumin (BSA) for 15 min at RT, respectively. Following incubation with primary antibodies and visualization of protein-antibody complexes, tissue sections were counterstained with Mayer’s hematoxylin and bluing reagent, dehydrated, cleared in xylene, and cover-slipped with Dako mounting medium (Agilent Technologies, Santa Clara, CA, USA). Known positive control sections were used for each antibody according to the datasheet, while negative controls were obtained by omitting the primary antibody.

Staining evaluation

Protein expression was evaluated at 10× and 20× magnification, using a Nikon ECLIPSE E400 light microscope (Nikon Instruments Europe, Amsterdam, The Netherlands) by two independent pathologists. Inflammatory infiltration was assessed on H&E stained tissue sections by the percent of area infiltrated by inflammatory cells, including mononuclear cells. A five-point (0–4) grading system was used:0: not detected;1: up to 25% infiltration;2: 26–49% infiltration;3: 50–75% infiltration;4: 76–100% infiltration.

Collagen structure was evaluated on Masson’s trichrome-stained sections (Special Stain Kit Masson’s Trichrome, DiaPath, Martinengo, Italy) using the following scale:0: loose, regular fibers;1: loose, irregular fibers;2: dense fibers;3: compact, coarse fibers.

Expression of CD4 [ 17 ], CD8 [ 18 ], CD68 [ 19 ] proteins was assessed as the percentage of positive inflammatory cells (0–100%).

CD20 [ 20 ] expression was scored on a binary scale (0–1). Vascularization was assessed by CD31 [ 21 ] staining using the following scale:0: few, thin-walled vessels;1: increased number of vessels with slight wall thickening;2: increased number of vessels with pronounced wall thickening.

The presence of fibroblasts was semi-quantitatively assessed using Vimentin [ 22 ] staining on a 0–4 scale.

Autofluorescence analysis of unstained preparations

The analysis of subepidermal collagen autofluorescence was performed on unstained tissue sections using a Nikon C1 confocal microscope with the red channel (543 nm laser excitation, 650 nm long-pass emission filter) and a 20× objective. Image acquisition parameters were kept constant across all samples. Three images were acquired from each section at a resolution of 1024 × 1024 px. Autofluorescence intensity was measured at five points within the ROI, each with dimensions of 80 × 80 px.

Statistical analysis

Statistical analysis of skin elasticity and hydration measurements was performed using IBM SPSS Statistics software (version 28.0.1.0; 2021). Mean values were compared using a paired t -test. For hypothesis testing, the following definitions were adopted:Null hypothesis: the treatment has no effect on the tested parameters.Alternative hypothesis: the treatment significantly affects the tested parameters.

Statistical analysis of histopathological results was performed using GraphPad Prism software (ver. 10.0.2; 2023). Tukey’s multiple comparisons test was used for evaluating differences between groups.

3. Results

  • A.Results of clinical assessment

Cutometric evaluation

  • 1.Skin elasticity measurements

The study showed statistical significance and a positive correlation of the effect on changes in skin elasticity at 5, 21 and 150 days after the procedure. The effect was observed soon after the procedure and showed gradual improvement over time. The mean elasticity values were as follows: baseline, 58.92; 5 days after the procedure 68.37 (+16.03% increase from baseline), 21 days after the procedure 72.11 (+22.38% increase) and 150 days after the procedure 73.27 (+24.35% increase). The statistical analyses and corresponding graphical results are shown in the tables and figures below ( Table 1 ; Figure 2 and Figure 3 ).

Table 1 Changes in skin elasticity before and after treatment.

Time PointMean ± SDΔ vs. Baseline (Mean ± SD)95% CI of Differencep -Value
Baseline58.92 ± 11.57–––
Day 568.37 ± 10.97+9.44 ± 2.55−10.40 to −8.49<0.001
Day 2172.11 ± 10.08+13.19 ± 2.75−14.22 to −12.16<0.001
Day 15073.27 ± 9.04+14.35 ± 4.32−15.96 to −12.73<0.001

Figure 2

Figure 2 Skin elasticity measurements before and after treatment. Boxplots represent skin elasticity values measured at four time points: baseline (before treatment), immediately after treatment, 21 days after treatment, and 150 days after treatment. An increase in both median and overall distribution of skin elasticity was observed directly after the procedure and maintained throughout the follow-up period. The results indicate a sustained and progressive improvement in skin elasticity over time.Figure 3

Figure 3 Skin elasticity changes over time. Skin elasticity was measured before treatment, immediately after treatment, and at follow-up visits on days 21 and 150. Baseline values were normalized to 100%. A progressive increase in elasticity was observed, rising to 116.03% immediately after treatment, 122.38% after 21 days, and 124.35% after 150 days. These results demonstrate a sustained improvement in skin elasticity following the procedure.- 2.Skin hydration measurements

The study showed statistical significance and positive correlation of the effect on changes in the level of skin hydration at 5 and 21 days after the procedure. The effect was observed soon after the procedure, remains similar at 21 days, and slightly decreases by 150 days. The mean hydration values were as follows: baseline, 58.76; immediately after the procedure, 60.23 (2.51% increase from baseline); 21 days after the procedure, 60.33 (2.69% increase); and 150 days after the procedure, 59.96 (2.04% increase). The statistical analyses and corresponding graphical results are shown in the tables and figures below ( Table 2 ; Figure 4 and Figure 5 ).

Table 2 Skin hydration before and after treatment.

Time PointMean ± SDΔ vs. Baseline (Mean ± SD)95% CI of Differencep -Value
Baseline58.76 ± 12.59–––
Day 560.23 ± 12.70+1.48 ± 3.30−2.71 to −0.240.02
Day 2160.33 ± 12.77+1.58 ± 3.78−2.99 to −0.170.03
Day 15059.96 ± 11.61+1.20 ± 4.18−2.76 to 0.360.13

Figure 4

Figure 4 Skin hydration measurements before and after treatment. Boxplots illustrate skin hydration values assessed at baseline, immediately after treatment, 21 days post-treatment, and 150 days post-treatment. Median hydration levels and variability showed only modest fluctuations across the follow-up period, indicating that skin hydration remained relatively stable following the procedure.Figure 5

Figure 5 Skin hydration changes over time. Skin hydration levels were expressed as percentages relative to baseline (100%) and measured immediately after treatment, as well as 21 and 150 days post-treatment. A slight increase in hydration was observed directly after treatment (102.51%) and at day 21 (102.69%), followed by stabilization at day 150 (102.04%). Overall, hydration values remained close to baseline, indicating minimal long-term changes.Healing time observation

Post-treatment effects were limited to mild skin redness. No swelling or other noticeable skin reactions were reported by the participants. The majority of patients did not experience significant reddening; redness was reported by 14 participants (46.67%), lasting 1–4 h, with an average duration of 1.85 h among those affected. Results are illustrated in the chart below ( Figure 6 ).

Figure 6

Figure 6 Healing time evaluation. The pie chart illustrates the distribution of healing times as assessed by the resolution of post-treatment erythema. More than half of the patients (53.33%) experienced no visible redness, while 23% showed redness lasting approximately 1 h. A smaller proportion reported erythema persisting for 2 h (10%), 3 h (10.33%), or up to 4 h (3.33%). These findings indicate that post-treatment reactions were generally mild and transient.Patient’s satisfaction evaluation

Patients’ satisfaction with the procedure was generally high. The majority of participants reported improvements in skin tightening, reduction in fine wrinkles, skin texture, and skin color. On a five-point scale (1 = no improvement, 5 = very good improvement), most patients rated the outcomes as moderate to very good. The detailed distribution of responses for each assessed feature is summarized in the table below ( Table 3 ).

Table 3 Patient satisfaction with treatment outcomes (self-assessment, N = X patients).

Improvment
Parameter:Very Good
Skin tension53.33%
Fine wrinkles20.00%
Skin structure–
Skin color–

Figure 7

Figure 7 Patient satisfaction following treatment. Patient satisfaction levels were assessed using a standardized questionnaire administered after completion of the treatment series. The figure illustrates the distribution of responses across predefined satisfaction categories, highlighting the overall positive perception of the intervention. The majority of patients reported high satisfaction, while only a small proportion expressed neutral or low satisfaction. These results emphasize the favorable patient-reported outcomes associated with the procedure.Expert evaluation

An independent team of seven experts assessed the changes in skin tension, fine wrinkles, skin structure, and skin color based on patient photographs taken before and five months after the procedure. The results are summarized below ( Table 4 ).

Table 4 Expert evaluation of clinical outcomes at 5 months (N = 7 experts).

Improvement
Parameter:Very Good
Skin tension39.52%
Fine wrinkles18.57%
Skin structure–
Skin color0.95%

Figure 8

Figure 8 Expert evaluation of fine wrinkle changes. The figure summarizes expert assessments of changes in fine wrinkles following treatment. Independent evaluators rated the degree of improvement using predefined clinical criteria. The distribution of expert ratings demonstrates measurable improvements in wrinkle appearance, supporting the objective efficacy of the intervention in addition to patient-reported outcomes. Due to missing or invalid responses, the total percentage of categories may be <100%. Missing answers are represented on the pie chart as the dark grey segment.- B.Results of histological assessment

Hematoxylin–eosin staining

Evaluation of inflammatory infiltration revealed a baseline level of mononuclear cell presence before the procedure, with a mean score of 1.22. Five days after the treatment, an increase in inflammatory infiltration was observed, reaching a mean score of 2.0, reflecting the expected acute tissue response. By day 21, the inflammatory infiltration had decreased to a mean score of 1.66, indicating a partial resolution of the inflammatory response and progression toward tissue recovery ( Figure 9 ; Table 5 ). Hematoxylin–eosin (H&E) staining was used to assess the overall tissue structure, including both cytoplasm and cell nuclei ( Figure 10 ).

Figure 9

Figure 9 Inflammatory infiltrate in hematoxylin–eosin (H&E) staining. Bar graph showing the semi-quantitative assessment of inflammatory infiltrate at baseline (black), day 5 (light gray), and day 21 (dark gray) after treatment. No statistically significant differences were observed between time points.Table 5 Statistical analysis results for inflammatory infiltration.

Tukey’s Multiple Comparisons TestMean Diff.95.00% CI of Diff.Adjusted p -Value
0 vs. 5−0.67−2.52 to 1.180.669
0 vs. 21−0.33−2.18 to 1.520.936
5 vs. 210.33−1.52 to 2.180.936

Figure 10

Figure 10 Representative hematoxylin–eosin staining of skin samples. Images are shown from left to right: immediately before treatment, 5 days after treatment, and 21 days after treatment. Staining was performed using an ECLIPSE E400 microscope (Nikon) at 20× magnification.CD68 (monocytes and macrophages)

Expression of CD68 proteins was assessed on a scale of 0–100% of inflammatory infiltrate cells. CD68 expression is associated with the presence of monocytes and macrophages, which are responsible for phagocytosing foreign substances. Prior to treatment, the average CD68 expression was 4.66% of inflammatory infiltrate cells. On day 5 post-procedure, this level increased to 10%, but by day 21, it decreased to 7.66% ( Figure 11 and Figure 12 ; Table 6 ).

Figure 11

Figure 11 Monocyte and macrophage (CD68+) expression in skin samples. Bar graph showing the percentage of CD68+ cells within the inflammatory infiltrate at baseline (black), day 5 (light gray), and day 21 (dark gray) after treatment. No statistically significant differences were observed between time points.Figure 12

Figure 12 Representative CD68+ immunohistochemical staining of skin samples. Images are shown from left to right: immediately before treatment, 5 days after treatment, and 21 days after treatment. Captured using an ECLIPSE E400 microscope (Nikon) at 20× magnification.Table 6 Statistical analysis results for monocytes and macrophages (CD68+) presence.

Tukey’s Multiple Comparisons TestMean Diff.95.00% CI of Diff.Adjusted p -Value
0 vs. 5−0.67−2.52 to 1.180.669
0 vs. 21−0.33−2.18 to 1.520.936
5 vs. 210.33−1.52 to 2.180.936

Lymphocytes T CD4 +

Expression of CD4 proteins was assessed on a scale representing 0–100% of inflammatory infiltrate cells. CD4 proteins are associated with the presence of T-helper (Th) lymphocytes and are directly linked to the MHC class II antigen recognition system. Prior to treatment, the average CD4 expression was 85% of inflammatory infiltrate cells. On the 5th day after the procedure, this level increased to 90%. By day 21 post-procedure, the proportion of CD4-positive cells decreased slightly, reaching an average of 86.66% ( Figure 13 and Figure 14 ; Table 7 ).

Figure 13

Figure 13 Th lymphocyte (CD4+) expression in skin samples. Bar graph showing the percentage of CD4+ cells within the inflammatory infiltrate at baseline (black), day 5 (light gray), and day 21 (dark gray) after treatment. No statistically significant differences were observed between time points.Figure 14

Figure 14 Representative CD4+ immunohistochemical staining of skin samples. Images are shown from left to right: immediately before treatment, 5 days after treatment, and 21 days after treatment. Captured using an ECLIPSE E400 microscope (Nikon) at 20× magnification.Table 7 Statistical analysis results for Th lymphocytes (CD4+) presence.

Tukey’s Multiple Comparisons TestMean Diff.95.00% CI of Diff.Adjusted p -Value
0 vs. 5−5.00−76.50 to 66.500.996
0 vs. 21−1.67−73.17 to 69.841.000
5 vs. 21mar.33−68.17 to 74.840.999

CD8 + (T lymphocytes)

Expression of CD8 proteins was assessed on a scale representing 0–100% of inflammatory infiltrate cells. CD8 proteins are associated with the presence of cytotoxic T lymphocytes (Tc lymphocytes/T-killer cells) and are directly linked to the MHC class I antigen recognition system. Before treatment, the average CD8 expression was 4.33% of inflammatory infiltrate cells. On the 5th day after the procedure, this level increased to 6.66%. By day 21 post-procedure, the proportion of CD8-positive cells decreased slightly, reaching an average of 5.66% ( Figure 15 and Figure 16 ; Table 8 ).

Figure 15

Figure 15 Tc lymphocyte (CD8+) expression in skin samples. Bar graph showing the percentage of CD8+ cells within the inflammatory infiltrate at baseline (black), day 5 (light gray), and day 21 (dark gray) after treatment. No statistically significant differences were observed between time points.Figure 16

Figure 16 Representative CD8+ immunohistochemical staining of skin samples. Images are presented from left to right: immediately before treatment, 5 days after treatment, and 21 days after treatment. Captured with an ECLIPSE E400 microscope (Nikon) at 20× magnification.Table 8 Statistical analysis results for Tc lymphocytes (CD8+) presence.

Tukey’s Multiple Comparisons TestMean Diff.95.00% CI of Diff.Adjusted p -Value
0 vs. 5−2.33−11.61 to 6.940.850
0 vs. 21−1.33−10.61 to 7.940.966
5 vs. 211.00−8.28 to 10.280.985

CD20 (B lymphocytes)

Expression of CD20 is indicative of the presence of B lymphocytes, which are responsible for recognizing antigens independently of the major histocompatibility complex and for producing antibodies and cytokines. The presence of B lymphocytes may significantly influence the development of inflammatory reactions following procedures, including the administration of hyaluronic acid-based fillers. An increased proportion of these cells should be viewed negatively regarding both the safety and longevity of such procedures. Prior to treatment, the average proportion of CD20-positive cells was 0.33% of inflammatory cells, and no significant changes were observed over the subsequent 21 days ( Figure 17 and Figure 18 ; Table 9 ).

Figure 17

Figure 17 B lymphocyte (CD20+) expression in skin samples. Bar graph showing the percentage of CD20+ cells within the inflammatory infiltrate at baseline (black), day 5 (light gray), and day 21 (dark gray) after treatment. No significant differences were observed between time points.Figure 18

Figure 18 Representative CD20+ immunohistochemical staining of skin samples. Images are shown from left to right: immediately before treatment, 5 days after treatment, and 21 days after treatment. Captured with an ECLIPSE E400 microscope (Nikon) at 20× magnification.Table 9 Statistical analysis results for B lymphocytes (CD20+) presence.

Tukey’s Multiple Comparisons TestMean Diff.95.00% CI of Diff.Adjusted p -Value
0 vs. 50.00−1.31 to 1.31>0.999
0 vs. 210.00−1.31 to 1.31>0.999
5 vs. 210.00−1.31 to 1.31>0.999

CD31 (PECAM-1)

CD31 expression is associated with vascular endothelium and reflects angiogenesis, which, alongside neocollagenesis, is one of the expected effects of tissue revitalization procedures. The number of vessels was evaluated using the following scale: 0—few, thin-walled vessels; 1—increased number of vessels with slight wall thickening; 2—increased number of vessels with pronounced wall thickening. Before the procedure, the CD31 level was 0. At both 5 and 21 days post-treatment, the level increased to an average of 0.66 ( Figure 19 and Figure 20 ; Table 10 ).

Figure 19

Figure 19 CD31 expression in skin samples. Bar graph showing mean CD31 expression levels (± SD) at day 5 (light gray) and day 21 (dark gray) after treatment. Expression was assessed using a semi-quantitative scoring scale ranging from 0 (no staining) to 2 (strong staining). No statistically significant differences were detected between time points.Figure 20

Figure 20 Representative CD31 immunohistochemical staining of skin samples. Images are presented from left to right: immediately before treatment, 5 days after treatment, and 21 days after treatment. Captured using an ECLIPSE E400 microscope (Nikon) at 20× magnification.Table 10 Statistical analysis results for CD31 expression.

Tukey’s Multiple Comparisons TestMean Diff.95.00% CI of Diff.Adjusted p -Value
0 vs. 5−0.67−1.73 to 0.400.264
0 vs. 21−0.67−1.73 to 0.400.264
5 vs. 210.00−1.07 to 1.07>0.999

Vimentin (presence of fibroblasts)

An increase in fibroblasts provides direct evidence of collagen production in the skin and ongoing tissue regeneration. Fibroblasts actively synthesize collagen, intercellular matrix fibers, and proteoglycans. The presence of fibroblasts was assessed using a semi-quantitative scale (0–4). Before treatment, the average fibroblast level was 1.66, increasing to 2.00 on day 5 and 2.33 by day 21 post-procedure. This corresponds to a 40% increase in fibroblasts at day 21 compared to baseline ( Figure 21 and Figure 22 ; Table 11 ).

Figure 21

Figure 21 Vimentin expression in skin samples. Bar graph showing mean vimentin expression levels (± SD) at baseline (black), day 5 (light gray), and day 21 (dark gray) after treatment. Expression was evaluated using a semi-quantitative scoring scale ranging from 0 (no staining) to 4 (strong staining). No statistically significant differences were observed between time points.Figure 22

Figure 22 Representative vimentin immunohistochemical staining of skin samples. Images are shown from left to right: immediately before treatment, 5 days after treatment, and 21 days after treatment. Captured using an ECLIPSE E400 microscope (Nikon) at 20× magnification.Table 11 Statistical analysis results for vimentin expression.

Tukey’s Multiple Comparisons TestMean Diff.95.00% CI of Diff.Adjusted p -Value
0 vs. 5−0.33−2.95 to 2.280.976
0 vs. 21−0.67−3.28 to 1.950.845
5 vs. 21−0.33−2.95 to 2.280.976

Autofluorescence analysis of unstained preparations

The aim of skin revitalization procedures, including infrared treatments, is to induce a measurable increase in collagen content. A statistically significant increase in collagen autofluorescence was observed in skin samples collected 5 days and 150 days after the procedure. No statistically significant changes were detected between samples taken before the procedure and those collected on day 21 post-treatment ( Figure 23 ; Table 12 ).

Figure 23

Figure 23 Subepidermal collagen autofluorescence. Representative images acquired using a 543 nm laser in combination with a 650 nm long-pass filter. Changes in collagen autofluorescence measured before the procedure (I0), immediately after the procedure (I0′), and on days 21 (I21) and 150 (I150) post-treatment. Circles, squares, triangles, and rhomboids represent individual data points within each group.Table 12 Statistical analysis results for collagen autofluorescence.

Tukey’s Multiple Comparisons TestMean Diff.95.00% CI of Diff.Adjusted p -Value
0 vs. 5−0.24−0.41 to −0.080.0007 (***)
0 vs. 21−0.02−0.18 to 0.140.982 (ns)
0 vs. 150−0.65−0.87 to −0.42<0.0001 (****)
0 vs. 5−0.24−0.41 to −0.080.0007 (***)
0 vs. 21−0.02−0.18 to 0.140.982 (ns)
0 vs. 150−0.65−0.87 to −0.42<0.0001 (****)

4. Discussion

The present study demonstrates that wide-spectrum, long-pulse infrared irradiation induces both early histological responses and sustained clinical improvements, supporting its role as an effective non-ablative modality for facial rejuvenation. The combination of cutometric measurements, subjective evaluations, and histological analyses provides a coherent picture in which thermal dermal stimulation initiates a controlled inflammatory cascade, followed by fibroblast activation, collagen remodeling, and progressive enhancement of skin elasticity. These findings not only corroborate the established mechanisms of non-ablative dermal heating but also offer new cellular-level evidence for this specific infrared device.

Cutometric analysis revealed significant improvements in skin elasticity as early as 5 days post-treatment, with progressive enhancement observed at 21 and 150 days ( Figure 2 and Figure 3 ; Table 1 ). This temporal pattern suggests that infrared-induced dermal heating initiates both immediate and sustained remodeling processes. Such long-term gains align with earlier studies, where infrared therapy was shown to stimulate neocollagenesis and matrix reorganization over several months [ 16 , 23 ]. Similar long-term improvements in elasticity were also reported by Lee et al., who demonstrated that far-infrared exposure significantly increased fibroblast collagen and elastin production and translated clinically into noticeable enhancement of skin tightness [ 23 ]. In contrast, skin hydration exhibited only modest improvements, peaking at 21 days and slightly declining by 150 days ( Figure 4 and Figure 5 ; Table 2 ), suggesting that hydration changes may reflect transient epidermal barrier modulation rather than durable dermal restructuring.

Patients and independent experts reported high satisfaction, particularly regarding skin tightening and reductions in fine wrinkles, in line with the objective cutometric results ( Figure 7 and Figure 8 ; Table 3 and Table 4 ). This agreement supports the clinical relevance of the treatment. However, noticeable discrepancies appeared in assessments of skin texture and color: patients tended to rate these improvements more positively than experts. These differences likely reflect distinct evaluation perspectives. Patients often perceive subtle, overall changes in skin appearance, whereas experts apply more stringent, standardized criteria focused on clearly measurable alterations. The more modest expert ratings for texture and color may also indicate that infrared thermolifting primarily affects deeper dermal structures, while superficial changes, such as pigmentation or fine surface irregularities—respond better to modalities like laser resurfacing or chemical peels [ 5 , 23 , 24 ]. This is consistent with findings by Lee et al., who reported minimal pigment improvement after far-infrared therapy [ 23 ], in contrast to the significant reductions demonstrated by Waibel and Schallen with the non-ablative fractional 1940 nm diode laser [ 24 ].

Histological analyses demonstrated a transient inflammatory infiltration, with its highest intensity observed at day 5 and resolving by day 21 ( Figure 9 and Figure 10 ; Table 5 ). This mild and self-limiting inflammatory response is in line with the expected tissue reaction to sub-ablative thermal exposure, which serves as a stimulus for wound-healing pathways without inducing overt tissue damage [ 25 ]. Because biopsies were collected after the immediate acute phase (first 48–72 h), the infiltrate consisted mainly of mononuclear cells, supporting the focus on CD4 + , CD8 + , CD20 + , and CD68 + markers rather than granulocyte-associated markers. Importantly, most changes in inflammatory markers (CD68, CD4, CD8, CD20), angiogenesis (CD31), and fibroblast activity (vimentin) were not statistically significant and should be interpreted as trends rather than definitive effects. These trends should also be interpreted in light of the small biopsy cohort, which may limit the sensitivity to detect subtle or heterogeneous tissue-level effects. The consistently low CD20 + levels suggest an absence of sustained humoral activation [ 26 ], while modest CD31 increases point toward early angiogenic activity [ 21 ]. A subtle and non-significant tendency toward increased CD68 + macrophages and CD4 + lymphocytes was observed, which may suggest the initiation of an early, remodeling-oriented immune response supporting matrix turnover and fibroblast activity ( Figure 11 , Figure 12 , Figure 13 and Figure 14 ; Table 6 and Table 7 ). Overall, the findings indicate a mild, controlled post-acute remodeling response, though studies including earlier biopsy time points and larger biopsy cohorts would better characterize the acute granulocytic phase.

Fibroblast stimulation is a central mechanism of dermal remodeling, leading to synthesis of new collagen and extracellular matrix proteins that restore skin elasticity [ 27 ]. In our study, the increase in vimentin-positive fibroblasts from baseline to day 21 ( Figure 21 and Figure 22 ; Table 11 ) should be viewed as a directional, rather than statistically conclusive, indicator of early cellular activation. More robust evidence of structural change was provided by collagen autofluorescence, which revealed significant increases at both 5 and 150 days ( Figure 23 ; Table 12 ), demonstrating a durable remodeling response. The early rise likely reflects immediate collagen fiber contraction—a mechanism previously described by Zelickson et al. following controlled dermal heating—whereas the pronounced increase at 150 days is consistent with sustained neocollagenesis and matrix reorganization [ 28 ]. This biphasic pattern accords with Goldberg’s findings that non-ablative 1320 nm Nd:YAG irradiation induces new papillary dermal collagen and visible clinical improvement, and with other infrared and radiofrequency studies showing that collagen renewal can continue for months after sub-ablative stimulation [ 29 ]. In line with these observations, Kubik et al. reported marked increases in fibroblast density and up to a 72% improvement in elasticity at 150 days, supporting the concept of prolonged infrared-driven remodeling [ 16 ]. Similar gains in intradermal collagen density reported by Wunsch and Matuschka following red and near-infrared photobiomodulation further underscore that fibroblast-mediated collagen renewal is a shared hallmark of multiple light-based rejuvenation modalities [ 30 ].

Compared with ablative modalities such as CO 2 or Er:YAG lasers, infrared therapy offers more modest improvements in epidermal features but demonstrates strong efficacy in dermal tightening with minimal downtime [ 8 , 31 ]. Ablative resurfacing remains the gold standard for treating texture irregularities and pigmentary changes, yet these benefits come at the cost of prolonged erythema, risk of post-inflammatory hyperpigmentation, and several days to weeks of recovery. In contrast, infrared thermolifting induces controlled sub-ablative heating of the dermis while preserving epidermal integrity, allowing patients to return to normal activity immediately after treatment. This favorable safety and tolerability profile was confirmed in our study, where no adverse events beyond transient erythema were observed. The short duration of post-treatment redness (mean 1.85 h) further underscores the minimally invasive nature of the procedure and aligns with previous reports describing infrared-based devices as consistently well tolerated, even in patients with darker phototypes or sensitive skin.

Although the biological effects of non-ablative thermal stimulation have been described for several infrared and mid-infrared modalities, detailed histological and autofluorescence data for this specific infrared device, and obtained under strictly monotherapy conditions without combination treatments have not been previously reported. Our study therefore provides the first structured, time-resolved evaluation of early and late remodeling responses for this platform, linking device-specific histological changes with objectively measured improvements in skin elasticity.

This study has several limitations. Histological analyses were performed in only three patients to minimize patient burden, which limits statistical robustness and generalizability. Biopsies were taken from the retroauricular area to avoid visible facial scarring—an ethical constraint in esthetic studies—but anatomical differences from facial skin may affect the applicability of these findings. The single-arm exploratory design allowed isolation of infrared-related tissue effects, yet the absence of a comparator group limits causal interpretation. The 150-day follow-up provides insight into medium-term remodeling, though long-term durability remains uncertain. Additionally, the ICDRG scale, used solely as a visual aid to standardize patient-reported erythema, is not validated for esthetic procedures and may introduce subjective bias. Future studies with larger biopsy cohorts, facial sampling when feasible, appropriate control arms, and extended follow-up will be essential to confirm and extend these preliminary results.

5. Conclusions

In summary, this study demonstrates that wide-spectrum, long-pulse infrared therapy induces favorable histological and clinical outcomes in patients with facial skin laxity and photodamage. The treatment was well tolerated, triggered transient but controlled inflammatory responses, stimulated fibroblast proliferation, promoted angiogenesis, and resulted in durable improvements in skin elasticity through collagen remodeling. While these findings support the regenerative potential of infrared energy, further validation in larger, controlled studies is needed to confirm long-term efficacy and to optimize treatment protocols for clinical practice.

标签
胶原

声明:中文精读 · 仅供学术参考。内容来自公开文献检索,不代表本人观点,不构成诊疗建议。 医疗美容需在正规医疗机构由执业医师实施。